Re: [lr-loadrunner] Load Generator

Tue, 07/19/2016 - 08:27
Read the documentation first, before you do anything. Before you install on a virtual machine, install on a physical machine and understand how it performs there. Before you accept the guidance from someone who does not understand what you do or why you do it but are mandating that you install
Categories: LoadRunner Lists

Re: Protocol Adviser in LR latest Version

Tue, 07/19/2016 - 08:27
Removed as you still need architectural knowledge to process the results of the protocol advisor.....which apparently the users of that feature did not have enough of to understand that DCOM was not the path of rightousness. - Wireshark - Installation guides (client requirements) -
Categories: LoadRunner Lists

SAP FIORI scripting experience

Tue, 07/19/2016 - 07:11
Hello All, Does any one work on SAP FIORI application before? I wanted which protocol does FIORI application supports and scripting challenges. Any help/suggestion on this. Thanks.
Categories: LoadRunner Lists

how to capture dynamic values in Citrix Protocol

Wed, 07/13/2016 - 07:48
Hi All, Currently I am working on Citrix protocol, we are facing many issues like unable to capture the values whatever we select in the drop down list and the text entered in the text box. Later we installed citrix agents on the citrix server and now we could see the values in the script.
Categories: LoadRunner Lists

Re: Max Time limit to "23:59:59" for "Start Group Schedule" design in Load Runner Controller 9.5 version

Wed, 07/13/2016 - 07:48
Have you tried the Real world schedule by group option for your scenario? - Hiranmaya On Thursday, 16 June 2016 18:17:07 UTC+5:30, Sivakumaar Thiyagarajan wrote: > > Hi, > > We are using Load Runner Controller 9.5 version for performance test suite > of one our product. We have a scenario where
Categories: LoadRunner Lists

Re: Server has shut down the connection prematurely

Mon, 07/11/2016 - 09:00
Try the 7th Option mentioned at the below link. I have developed these resolutions based on my personnel experience with testing: http://automation-performance.blogspot.in/2011/05/server-xxxx-has-shut-down-connection.html On Tuesday, 9 February 2016 05:30:05 UTC+5:30, prasanna kothawade wrote:
Categories: LoadRunner Lists

Re: LoadRunner for FREE

Sun, 07/10/2016 - 18:20
Read the license agreement. It explains all..... On Sunday, July 10, 2016 at 6:17:27 PM UTC-4, Selvakr wrote: > > Shane - > > Does this mean there is no trail license and anyone can download LR12 and > use it for their testing with 50 users just like JMeter? > > > Selva > > On Wednesday, 10
Categories: LoadRunner Lists

Re: Performance testing in Call Centre

Sat, 07/09/2016 - 09:29
Hi Is there any reference how to design the performance testing for a call centre where the agent receive the phone call? Thanks
Categories: LoadRunner Lists

Re: Dynamic Value in Response Header and Need to corelate

Sat, 07/02/2016 - 16:08
Go to Recording Options / HTTP properties / Advanced / Headers and add 'x-csrf-token' or select 'Record header not in list'. Then record or regenerate the script. Note: the header name (in web_add_header) is without the colon (:) or space. The right boundary in web_reg_save_param should be \r\n
Categories: LoadRunner Lists

Re: Max no of iterations for vugrn 12 trial version

Sat, 07/02/2016 - 16:08
Turning off the debugger will also help, see: https://groups.google.com/d/msg/lr-loadrunner/Cxyjcf1CIWA/a9NyP7GfaT4J But just to generate a large text (XML) file it is probably easier/faster to use Perl instead (installed as part of Vugen). André On Wednesday, 29 June 2016 16:35:56 UTC+2, James
Categories: LoadRunner Lists

Re: How to kill session timeout for a browser in LoadRunner?

Mon, 06/27/2016 - 07:52
Place a protocol analyzer like wireshark on the wire while you close your browser session manually which cleans up the session as you desire. Look to your test code. If the transfer which takes place is not captured, then impose the request on your code. If nothing is transferred, then you
Categories: LoadRunner Lists

Re: RTE Protocol Scripts Failing in Performance Center :: TE_Connect.. Failed to Connect

Wed, 05/11/2016 - 09:20
Here are the steps that I followed to overcome this issue. 1. Telnet Port: 23 ( Default ) & SSH Port: 22 ( Default ) 2. While running through VuGen, there is some component which am unsure that opens connectivity with port 22 which is a SSH port. 3. But while running through ALM, this component is
Categories: LoadRunner Lists

Re: Correlating graphs and impacts on each

Tue, 05/10/2016 - 09:28
If response time is increased , the transaction per seconds will decreased because total script execution time will increase . On Wednesday, March 9, 2016 at 6:11:00 PM UTC-5, karthikeyuan subramanian wrote: > > If response time increases what will be the impact in transaction per > second
Categories: LoadRunner Lists

Re: How to analyze response time and other metrics for each tenant for a script running in multi-tenant environment.

Tue, 05/10/2016 - 09:28
@JamesPulley. Thanks a lot!! I got what I needed. I was earlier thinking of writing if else condition for parameter name for each tenant, but that's lot of work when no. of tenants increase. Thanks again. On Monday, May 9, 2016 at 7:26:20 PM UTC+5:30, James Pulley wrote: > > Why not append the
Categories: LoadRunner Lists

Re: Restrict the Captuiring of some values in Drop down list

Mon, 05/02/2016 - 10:03
Thanks for your reply I got how to separate 2 drop downs that are written in simple html tags using some c skills now I am exploring about capturing the whole XML tree I will get back to you if I have doubt once again thanks. On Sunday, April 17, 2016 at 7:18:28 PM UTC+5:30, Raja Rk wrote: > >
Categories: LoadRunner Lists

Re: [lr-loadrunner] Re: 'Insufficient records for parameter 'xxxx' in table to provide the Vuser with unique data

Wed, 04/27/2016 - 18:11
Your assertion on unique doesn't hold. This was in at least the 5.x product line dating to 1997. I pulled my training manual for LR 6.0 DB virtual user from 1998: Page 2-17 covers unique read from table and page 2-22 covers Unique Number. Unique holds within groups, but not across groups
Categories: LoadRunner Lists

Re: Controller showing Failed to call bind function from TrapWSPConnect. The system returned error code 10055

Wed, 04/27/2016 - 17:49
Hi Thank you the answer. I try to put the think time on the script but encounter same issue on load generator with this message. I install load runner agent on some PCs and run using them and there is no issue. Is there setting we need to consider on load generator machine? Thanks On Monday,
Categories: LoadRunner Lists

Re: lr function or C code to remove commas from number (eg: 10,22,30)

Wed, 04/27/2016 - 09:52
I don't understand why splitting up a string into sub strings using strtok is considered the solution. Just removing the commas is easier. char *delcomma(char *str) { char *p, *q; for (p = q = str; *p; p++) if (*p != ',') *q++ = *p; *q = 0; return str; } Save the new value
Categories: LoadRunner Lists

Connecting to Oracle DB using LR Vugen

Thu, 04/21/2016 - 11:09
Hi I am looking for sample script using C VUser or ODBC protocol, please advise.. I tried to use this function: lrd_open_connection, I was not sucessful thanks
Categories: LoadRunner Lists

Re: correlation parameter helps

Wed, 04/20/2016 - 18:01
Hi I try to correlate a param as: web_reg_save_param("KEY1", "LB=WHR_SELF_SERVICE.WHR_JOBREQ_APPR.GBL?Page= WHR_JOBREQ_APPR&Action=U&KEY1=", "RB=&TargetFrameName=None", LAST); web_reg_save_param("KEY11", "LB= whrsys2_2/SS/HRMS/c/WHR_SELF_SERVICE.WHR_JOB_REQ_WEB_V.GBL?Page= WHR_JOB_REQ3
Categories: LoadRunner Lists